APC AP7921B : RACK PDU SWITCHED 1U 16A

R17 590.00
(R20 228.50 incl VAT)
Short description:

Switched Rack Power Distribution Units provide advanced load management plus on/off control at the outlet level for power cycling and delayed power sequencing

07-DIS-PDU-007

Key Features

  • Rack Height - 1U
  • Output Connections - (8) IEC 320 C13
  • Nominal Output Voltage - 208V, 230V
  • Nominal Input Voltage - 200V, 208V, 230V
  • Input Connections - IEC-320 C20
  • Cord Length - 2.5meters

_______________________________________

 

Marketing features

Remote Management Capabilities

Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Alarm Thresholds

Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

Local Current Monitoring Display

The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.

 

Adaptability

Single input power source

Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

Wide range of input and output connections

Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.

Rack-Mountable

Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.

 

Manageability

Network Management Capabilities

Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Multi-tier user access

Supports up to four access levels - Administrator, Device User, Read-Only User and Network-only User - with user name and password requirements.

Network port sharing

Allows four rack PDUs to be connected using In and Out ports so that only one network connection is necessary.

Integrates with StruxureWare Data Center Expert

An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network

Power Delays

Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.

Local Current Monitoring Display

The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)

Remote Individual Outlet Control

Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Alarm Thresholds

Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)

Flash Upgradeable

Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)

 

Output

Maximum Total Current Draw 16

Input

Input frequency 50/60 Hz
Acceptable Input Voltage 200-240VAC
Number of Power Cords 1
Load Capacity 3680VA
Maximum Input Current 20A
Regulatory Derated Input Current (North America) 16A

Physical

Maximum Height 44MM, 4.4CM
Maximum Width 445MM, 44.5CM
Maximum Depth 108MM, 10.8CM
Net Weight 2.27KG
Color Black
Environmental
Operating Temperature 0 - 45 °C
Operating Relative Humidity 0 - 95 %
Operating Elevation 0-3000meters
Storage Temperature -25 - 65 °C
Storage Relative Humidity 0 - 95 %
Storage Elevation 0-15000meters

Conformance

Approvals cUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, UL 60950, UL Listed, VDE, VCCI
Standard warranty 2 years repair or replace

Sustainable Offer Status

RoHS Compliant
REACH REACH: Contains No SVHCs
Battery Directive Compliant
Proposition 65 Warning Available in Documentation tab